2016 Audi Q5
Mileage
798,025
Service Date
4/28/2026
Services Performed
- VERIFIED COMPLAINT, THERE ARE MISFIRES THAT ARE NOT REGISTERING IN THE ENGINE ECU BUT TO HAVE O2 SENSOR FAULT CODES, FOCUS ON THE COMPLAINT, REMOVE AND INSPECT SPARK PLUGS SEEM AGED , REPLACE THEM AND RE TEST HESITATION HELP BUT STILL MINOR SCALE, INSPECT CARBON BUILD CLEAN VALVES AND ROAD TEST CHECK OK AT THIS TIME, CHECK ENGINE LIGHT CAME ON, FOUND CODE FOR O2 SENSOR UPSTREAM TEST AND VERIFY FAILURE SLOW DOWN AT TIMES, REPLACE CLEAR CODE AND RE TEST CHECK OK AT THIS TIME
- SPARK PLUGS – Remove & Replace – In-Line4
- INTAKE MANIFOLD – Remove & Replace – In-Line4, Gas/Ethanol Lower – [Includes: Additional time for use of scan tool to perform this procedure.]
- OXYGEN SENSOR – Remove & Replace – In-Line4 Front
ROBB W. gave our service a 5 star review on 4/29/2026